Skip to product information
1 of 1

DAIKIN SKY AIR FTXC100A-AV 10.0kW Reverse Cycle Split System Air Conditioner | 1 Phase

DAIKIN SKY AIR FTXC100A-AV 10.0kW Reverse Cycle Split System Air Conditioner | 1 Phase

Contact for price
Contact for price
Sale Sold out

This DAIKIN SKY AIR FTXC100A-AV 10.0kW Reverse Cycle Split System Air Conditioner is perfect for cooling or heating your space with 10.0 kW cooling and 11.2 kW heating power. Enjoy efficient and powerful air conditioning, all controlled with a convenient one-phase system.

Get a Quote View full details
Product Specification
 Model Name Indoor unit FTXC100AV1A
Outdoor unit RXC100AV1A
Power supply 1 Phase, 220-240V, 50Hz
Cooling capacity1,3 Rated (Min. – Max.)  kW 10.0(5.0-11.2)
Heating capacity2,3 Rated (Min. – Max.)  kW 11.2(5.1-12.5)
Power consumption Cooling kW 3.11
Heating kW 3.48
EER Cooling kW/kW 3.22
COP Heating kW/kW 3.22
AEER Cooling 3.17
ACOP Heating 3.17
TCSPF (Cooling) Commercial / Residential Hot 5.03 / 4.63
Average 5.13 / 4.18
Cold 5.49 / 4.33
HSPF (Heating) Commercial / Residential Hot 4.66 / 4.64
Average 4.25 / 3.95
Cold 3.77 / 3.42
Indoor unit Colour Fresh white
Airflow rate (H / M / L) /s 433 / 383 / 317
m3/min 26.0 / 23.0 / 19.0
Sound pressure level4 (H / M / L) dB(A) 49.0 / 45.0 / 41.0
Sound power level (H / M / L) dB(A) 65 / 62 / 58
Dimensions (HXWXD) mm 340X1,200X240
Machine weight kg 17
Certified operation range Cooling °CWB 14 to 25
Heating °CDB 15 to 27
Outdoor unit Colour Ivory White
Compressor Type Hermetically sealed swing type
Motor output kW 3.3
Refrigerant charge (R-32)  kg 3.75(Charged for 30 m)
Sound pressure level 4 Cooling / Heating dB(A) 51 / 53
Night quiet mode dB(A) 47
Sound power level dB(A) 70
Dimensions (HXWXD) mm 1,430X940X320
Machine weight kg 93
Certified operation range Cooling °CDB -5 to 50
Heating °CWB -15 to 15.5
Piping connections Liquid (Flare) mm o/ 9.5
Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP13 (I.D.o/ 13XO.D. o/ 18)
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 75 (Equivalent length 90)
Max. installation height difference m 30
Heat insulation Both liquid and gas piping