Upgrade your commercial space with the Mitsubishi Electric PKA-M71KAL.TH 7.1kW Light Commercial Wall Split System. Enjoy 7.1kW cooling and 8.0kW heating power, along with advanced features like wireless controller for easy operation. Perfect for single-phase connection and energy-efficient R32 refrigerant.

View full details
Would you like to include Installation Service? Base price is AUD $750 including GST (Metro Brisbane only)

***Disclaimer: This installation price of AUD $750 (including GST) is only valid for metro Brisbane. The actual installation cost may vary depending on the type of installation needed. Our service technicians will discuss the final price with you via call or email.***
Product Specification
PKA-M Series (Wall Mounted)
Indoor Unit PKA-M71KAL
Outdoor Unit PUZ-ZM71VHA-A
Refrigerant R32
Power Supply (V, Phase, Hz) V: 230V, Single-phase, 50Hz Y: 400V, Three-phase, 50Hz
Capacity kW 3.30 – 7.10 – 8.10
[Min-Rated*4-Max]
Total Input [Rated]*4 kW 1.86
AEER/EER 3.61/3.81
Cooling Running Current [Rated]*4 A 9.48
Sound         In (Lo-Mid-Hi) PressureLevel*2                  Out (PWL)  dB(A) 39 – 42 – 45
47 (67)
Air Volume (In) Lo-Mid-Hi L/S 300 – 333 – 367
Capacity kW kW A 3.50 – 8.00 – 10.20
[Min-Rated*5-Max]
Total Input [Rated]*5 2.12
ACOP/COP 3.60/3.77
Heating Running Current [Rated]*5 10.00
Sound         In (Lo-Mid-Hi) PressureLevel*2                  Out (PWL)  dB(A) 39 – 42 – 45
51 (70)
Air Volume (In) Lo-Mid-Hi L/S 300 – 333 – 367
Max. Running CurrentInput [Rated] A 19.43
kW 0.06
Indoor Dimensions [HxWxD] mm 365 × 1170 × 295
Unit
Weight kg 21.0
 Outdoor Dimensions [HxWxD] mm 943 × 950 × 330 (+25)
Weight kg 70.0
Unit
Breaker Size A 25
Ext.          Diameter [Liquid/Gas] mm ø9.52/ø15.88
Piping      Max. Length/Height m 50/30
Guaranteed                 Cooling*3 °C -5 (-15) ~ 52
Operating Range[Outdoor]                    Heating °C -20 ~ 21
Pre-Charge Refrigerant kg 2.8 (30m)
Additional Refrigerant g/m 40